Bosch Bottom Mount Refrigerator Magnetic Valve

{0 Comments}

A magnetic valve is used in cooling cycle for energy saving option. The valve is installed in cooling circuit after the dryer. The valve closes the cooling circuit when the compressor switches off, as a result pressurized refrigerant remains between the valve and compressor. Before the compressor switches on according to the set point temperature, the valve opens the cooling circuit and pressurized refrigerant flows in to the evaporator, as a result it is enabled to have cooling performance without compressor runs.

The solenoid valve is switched on 12 s. before compressor start and switched off immediately with the compressor stop.

If the ambient temperature is higher than “35°C / 95 °F ” or the supply voltage is lower than “107V US / 215 V EU the stop valve pre running time changes to 3 min

If the ambient temperature is higher than “35°C / 95 °F ” and the supply voltage is lower than “107V US / 215 V EU ”the stop valve pre running time changes to ‘’8 min

Bosch Bottom Mount Refrigerator Magnetic Valve Bosch Bottom Mount Refrigerator Magnetic Valve

Leave a Comment

Your email address will not be published.